
In various research projects of the Studiengesellschaft, the fire behaviour of hollow section composite columns has been investigated in the past with a large number of varied boundary conditions. The results of these …
In various research projects of the Studiengesellschaft, the fire behaviour of hollow section composite columns has been investigated in the past with a large number of varied boundary conditions. The results of these projects with regard to the fire protection assessment of large cross-sectional dimensions (> 200 nun) were reflected in the introduction to the building inspectorate according to ''Mitteilungen des Instituts für Bautechnik 1988'', issue 4, pp. 104-109. In order to be able to carry out an assessment in the event of fire for smaller cross-sectional dimensions11 of 180 to 140 mm side length or diameter, this research project with final report was initiated by CIDECT (Comite International pour le Developpement et l'Etude de la Construction Tubulaire, Paris) and co-financed to 50 %. The hollow sections required for the fire tests were provided free of charge by Mannesmannröhren-Werke AG and Hoesch AG. STUDIENGESELLSCHAFT FÜR ANWENDUNGSTECHNIK VON EINSEN UND STAHL e.V.
Machine-translated title and description. The document itself is in German.

Payment by card (Stripe) or invoice (DE, AT, CH). Download link by email: automatically after ordering by card, after order approval for invoice (valid for 30 days). Terms
Digital download
Other parts and editions as well as neighbouring documents of the same series.

P 86 1.2 - Influence of enclosure components on fire development in industrial halls Publication: 1982 Authors: Prof. Dr.-Ing. habil. U. Schneider
available anytime
€20.00
excl. VAT

P 86 2.10 - Fire behaviour and dimensioning of connections to extend the fire resistance period of composite structures As part of the major fire protection research programme "Fire behaviour of steel and steel composite structures", a great deal of attention is paid to the investigation of composite components such as columns, beams, floors and grids. They were necessary because the composite construction method, which has been placed on a new footing in recent years - promoted by numerous projects of the Studiengesellschaft, among others - has met with a great response in the construction industry. Numerous applications in industrial and administrative buildings, hospitals, etc. demonstrate this. Some of these projects have to fulfil fire protection requirements. However, since only individual tests with composite components were available, which also only took into account singular designs, it was necessary to carry out such investigations with validity for the various types of construction. It soon became apparent that it was also necessary to investigate the fire behaviour of standard connections of composite components in order to finally classify them into a fire resistance class. This task was carried out as sub-project 2.lo "Fire behaviour of transom connections on composite columns made of rolled sections set in concrete and hollow sections set in concrete". Already during the implementation, but even more so during the final elaboration, it became apparent that due to the special features of the composite construction method, the question could be formulated more generally and extended to the load-bearing behaviour of the composite beam system with the aim of mode of action and design to include measures to extend the fire resistance period. The results of these complex investigations are presented to the professional world in this report. They show practitioners several ways to design the fire protection of beams and connections. To take account of this extension, the more ambitious title "Fire behaviour and design of connections to extend the fire resistance period of composite structures" was chosen. It is to the authors' credit that this report provides the basic principles of fire protection assessment and dimensioning for direct application, all the more so because these principles not only apply to individual cases, but can also be adopted in the standards (DIN 4lo2). All steps of the investigations were accompanied by a group of advisors consisting of competent practitioners with experience in the field of joints between steel and solid construction. This ensured close practical relevance. We would therefore like to express our gratitude to these gentlemen working on a voluntary basis. STUDIENGESELLSCHAFT FUR ANWENDUNGSTECHNIK VON EISEN UND STAHL e.V. Publication: 1984 Authors: Dipl.-Ing. T. Dorn, Dr.-Ing. R. Haß, Prof. Dr.-Ing. U. Quast
available anytime
€40.00
excl. VAT

P 86 2.2 - Fire behaviour of composite columns with consideration of the different column/beam connections The design and construction of composite columns - structural steel, concrete and reinforcing steel are rigidly bonded - at room temperature conditions has been regulated by DIN 18 806 Part 1 /25/. These columns are not included in DIN 4102 Part 4 /22/ - a catalogue of components divided into fire resistance classes - due to a lack of test experience. For this reason, a research project /1/ was carried out between 1978 and 1980 on behalf of the Studiengesellschaft für Anwendungstechnik von Eisen und Stahl e.V., Düsseldorf, with financial support from the European Coal and Steel Community, Brussels, by the Institute for Building Materials, Solid Construction and Fire Protection at the Technical University of Braunschweig, in which the fire behaviour of composite columns was investigated. These tests were carried out with precisely defined static support conditions - hinged or clamped. The exact definition of the support conditions is essential for a theoretical interpretation of the tests. In a fire protection assessment, however, their selection should also fulfil the conditions that exist in practice. This research report presents the results of tests on steel composite columns that were tested under practical storage conditions. A test set-up was developed that made it possible to realistically simulate the load-bearing and deformation behaviour of columns exposed to fire in building construction. The constraint stress resulting from the displacement of large floor systems under fire exposure could be taken into account. This research project was financially supported by the Studiengesellschaft für Anwendungstechnik von Eisen und Stahl e.V., Düsseldorf, and the Federal Ministry of Research and Technology, Bonn. Publication: 1985 Authors: Dipl.-Ing. R. Haß, Prof. Dr.-Ing. U. Quast
available anytime
€50.00
excl. VAT

P 86 2.3 Volume 1 - Theory, calculation principles and examples At the instigation of the Studiengemeinschaft für Anwendungstechnik von Eisen und Stahl e.V., Düsseldorf, a research project on the mathematical investigation of composite columns under fire exposure was funded in the years 1980-1984. The aim of the research project was to produce load tables for which the calculation principles derived from experimental investigations were to be used. The following cross-sections were analysed: - Composite cross-sections with rolled sections embedded in concrete - Composite cross-sections with hollow sections encased in concrete The calculation results are presented in the form of tables and diagrams. The entire scope of the research project is divided into three report volumes in order to provide the user with clear and simple handling of the calculation values. - VOLUME 1 Theory, calculation principles and examples This volume contains the theory and calculation principles for determining the load-bearing capacity of composite columns made of steel and concrete under the influence of fire. Detailed information and examples of the entire calculation scope of the research project are provided. - VOLUME 2 Load tables and application examples This volume contains the calculated loads in the form of tables. The use of the tables is explained using examples. - VOLUME 3 Load charts and application examples. This volume contains the calculated load capacities in the form of diagrams. The use of the diagrams is explained using examples. The research project was financially supported by the following institutions: - Studiengesellschaft für Anwendungstechnik für Eisen und Stahl e.V., Düsseldorf. Project P 86 , sub-project 2.3 - Federal Ministry of Research and Technology, Bonn. Project BAU 6004 The investigations were carried out at the Institute for Building Materials, Concrete Construction and Fire Protection (IBMB) at the TU Braunschweig. The basic principles for calculating fire-stressed components developed in the special research area 148 "Fire behaviour of building materials and components" at the Technical University of Braunschweig were used for this project. Publication: 1985 Authors: Prof. Dr.-Ing. U. Quast, Dipl.-Ing. K. Rudolph
available anytime
€20.00
excl. VAT
Payment by card (Stripe) or invoice (DE, AT, CH). Download link by email: automatically after ordering by card, after order approval for invoice (valid for 30 days). Terms